If you’ve ever engineered a power supply system—whether for a server, industrial motor, or even a medical device—you’ve probably run into hold-up time. It’s that unglamorous but make-or-design metric: the amount of time a power supply can keep delivering stable, rated output power when the main AC input drops out. For applications like data centers or life-support equipment, a missed hold-up window can mean corrupted data, shut-down systems, or even safety hazards. As a PFC power supply supplier with 12 years building solutions for industrial and commercial OEMs, I talk to engineers every week who ask: how exactly does power factor correction (PFC) impact this critical hold-up time? The answer isn’t as straightforward as “PFC adds time” or “PFC cuts it”—it’s rooted in the design tradeoffs we make when balancing power efficiency, grid compliance, and the energy storage that powers hold-up periods. Let’s break this down, starting with what hold-up time actually relies on. PFC Power Supply

First, a quick refresher: hold-up time depends almost entirely on the energy stored in the bulk capacitor of the power supply’s front-end. That big capacitor, usually rated in microfarads (µF) or farads (for higher-power units), charges from the rectified AC input during normal operation. When the AC cuts out, that capacitor discharges its stored energy to keep the downstream DC-DC converter running. The formula for hold-up time is straightforward enough, and it gives the baseline: ( T_{hold} = \frac{1}{2} \times C \times \frac{(V_{bulk_max}^2 – V_{bulk_min}^2)}{P_{out}} ). Here, C is the bulk capacitance, V_bulk_max is the capacitor’s peak voltage at full charge, V_bulk_min is the minimum voltage the DC-DC converter can accept before it shuts down, and P_out is the power the supply delivers to the load. If you cram more capacitance into the front end, you get more stored energy, so longer hold-up time—right? That’s the rule of thumb, but it’s where PFC changes the game.
Wait, let’s back up: traditional power supplies (those without PFC) have a front-end rectifier that pulls current only near the peak of the AC sine wave. That means the bulk capacitor charges to the peak of the AC input, which is 1.414 times the rms line voltage. For a 120V AC line, that peak is ~170V, for 230V AC it’s ~325V. The catch with these non-PFC supplies is their power factor: typically 0.6 or lower, meaning they waste a lot of energy relative to their apparent power drawn from the grid. But their bulk capacitor is sized such that during normal operation, it only discharges between AC peaks—so the voltage on the bus never drops too far between peaks. That means the V_bulk_min is often higher for non-PFC supplies, because there’s no active regulation keeping the bus voltage stable.
Now, active PFC (the kind most modern power supplies use, especially for 80 PLUS efficiency ratings) changes that. Active PFC is a switching circuit that regulates the front-end bus voltage to a fixed, higher DC level—usually 380V for a 230V AC input, or 390V for 120V AC—regardless of line voltage. The big advantage here is power factor: active PFC pushes power factors to 0.95 or higher, meeting international standards like IEC 61000-3-2 that limit harmonic current distortion. But that fixed bus voltage is what reshapes hold-up time calculations. Let’s walk through a real example from our engineering team: take a 1kW power supply, designed for industrial machinery, that needs 20ms of hold-up time at full load.
If we built a non-PFC supply for 230V AC, its bulk capacitor would be ~220µF, and its bus would swing from ~325V peak (max) down to ~200V (min) between AC peaks. Using the hold-up formula, that gives ~18ms—close, but to hit 20ms we’d need a bigger capacitor, ~250µF, which adds cost and size. Now, switch to an active PFC supply for the same 1kW load, same 20ms hold-up requirement. The fixed bus voltage is 380V, so V_bulk_max is 380V, but V_bulk_min for the DC-DC converter is still, say, 200V (wait—no, actually, because active PFC keeps the bus at 380V during normal operation, so when AC drops out, the bus can discharge all the way down to the converter’s minimum operating voltage, right? Wait, no—let’s correct that. In active PFC designs, the bulk capacitor is sized to maintain the bus voltage at 380V during normal operation, so when AC cuts out, we can use the full range of the capacitor’s voltage swing, from 380V down to the DC-DC converter’s minimum threshold, which is often around 180V for high-power supplies. Wait, but in our example, let’s do the math properly: T_hold = 0.5 * C * (380² – 180²) / 1000W. Solving for C to get 20ms (0.02s): C = (0.02 * 1000 * 2) / (380² – 180²) = 40 / (144400 – 32400) = 40 / 112000 ≈ 0.000357 F, or 357µF. Wait, that’s way bigger than the non-PFC 250µF we had earlier. So that means active PFC requires more capacitance for the same hold-up time? That’s a key point most engineers miss.
But hold on—why can’t we make the capacitor smaller? Because non-PFC supplies have a lower V_bulk_min relative to their V_bulk_max swing, but their average power factor is low, so they draw more current, which means between AC peaks, the voltage drop is steeper. Active PFC’s higher power factor means less current draw, so wait—let’s adjust for load. If the non-PFC supply has a power factor of 0.6, its apparent power is 1kW / 0.6 ≈ 1667VA, so the current drawn from the grid is higher, which means the bus voltage drops faster between peaks. That’s why non-PFC supplies need to size their bulk capacitors to prevent the bus from dropping below the DC-DC’s minimum during normal operation. But active PFC’s 0.95 power factor means its apparent power is 1kW / 0.95 ≈ 1053VA, so current draw is 36% lower—so the bus voltage discharges more slowly when AC cuts out? Wait, no, when AC cuts out, the discharge rate is purely a function of load power and capacitance: I = P_out / V_bulk, so higher load means faster discharge. So for the same P_out, the discharge rate is almost identical for PFC and non-PFC. The big difference is the bus voltage range. Non-PFC’s bus swings from ~325V to ~200V (a difference of 125V), while active PFC’s swings from 380V to 180V (a difference of 200V). That larger voltage delta means more stored energy for the same capacitor: stored energy is 0.5CV², so the difference between max and min is 0.5C(Vmax² – Vmin²), which for active PFC is a bigger number than non-PFC, even with a higher Vmin. That’s why our example above showed the active PFC supply needing a ~40% bigger capacitor than the non-PFC one for the same hold-up time.
But here’s the tradeoff we make at our company as a PFC power supply supplier: bigger capacitors add cost, size, and maybe a tiny bit of efficiency loss, but active PFC gives us consistent grid compliance and better performance during brownouts, which matters more for most OEMs now. Let’s talk about edge cases. What if you’re designing a low-power supply, say 100W for an IoT sensor that needs 10ms of hold-up time? The difference between PFC and non-PFC is smaller. A non-PFC supply would need ~25µF, active PFC ~30µF—hardly a noticeable size difference. But for high-power supplies, like 10kW industrial chargers that need 100ms of hold-up time, that delta gets big: non-PFC might need ~2mF, active PFC ~2.8mF, which adds weight and cost. But why would anyone choose PFC then? Because without active PFC, the charger would fail grid harmonic standards in most countries, leading to fines or rejection by distributors. That’s the balance.
Another factor: PFC topology. Not all active PFC is the same. There’s continuous conduction mode (CCM) and discontinuous conduction mode (DCM) PFC. CCM PFC is more efficient at high power, above ~300W, so it’s the standard for most commercial and industrial supplies. DCM is cheaper for low-power supplies, but its bus voltage is more variable, similar to non-PFC, so its hold-up time performance is closer to non-PFC than CCM. Our team has seen clients try to skimp on CCM PFC for hold-up time, only to run into issues when a new regulation requires them to upgrade to CCM, forcing them to rework their bulk capacitor sizing.
Wait, let’s also address a common myth: some engineers think PFC reduces hold-up time because of switching losses in the PFC circuit. It’s true that the PFC switch, inductor, and diode add a small amount of power loss, usually 2-5% of total output power. That means the load on the bulk capacitor is slightly higher (since the PFC circuits draw some power), which would make hold-up time a tiny bit shorter. But that loss is negligible compared to the voltage delta effect we talked about earlier. In our 1kW example, a 3% loss adds 30W of load, so hold-up time would drop from 20ms to ~19.5ms—hardly enough to notice, and we can compensate by adjusting the capacitor size by 5% to get back to the target.
Another real-world example from a client of ours: a manufacturer of medical imaging equipment needed a power supply with 50ms of hold-up time to prevent image corruption during brief grid blips. They initially went with a non-PFC supply, which used a 1.2mF bulk capacitor, but it failed IEC 61000-3-2 harmonic testing, so they had to switch to active PFC. We sized the bulk capacitor to 1.6mF, which met both the hold-up time requirement and the harmonic standard, and the client has been using it for 4 years without issues. That’s a case where PFC added a small cost and size, but it was non-negotiable for compliance.
Now, what about power factor correction for hold-up time in off-grid or renewable energy systems? For off-grid inverters, which use PFC to manage battery charging, hold-up time is even more critical. In this case, the “AC input” is the battery bank, so the PFC circuit is drawing power from the battery, and hold-up time would be the time the inverter can run if the battery drops below a certain voltage. Here, the same formula applies, but the Vmax and Vmin are battery voltage levels, not rectified AC peaks. Active PFC allows the inverter to draw power more consistently from the battery, so the voltage drop is more predictable, making it easier to calculate hold-up time accurately. That’s why off-grid inverters almost exclusively use active PFC—they need reliable, consistent hold-up time without the variability of non-PFC designs.
Let’s wrap this up with key takeaways, from a supplier who’s dealt with hundreds of these projects:
- Active PFC changes the hold-up time calculation primarily by increasing the bus voltage swing (from Vpeak of AC to a fixed regulated DC bus), which generally requires a larger bulk capacitor to maintain the same hold-up time as a non-PFC supply.
- This tradeoff is almost always worth it for commercial, industrial, and medical applications: active PFC meets global harmonic standards, reduces energy waste, and provides more consistent performance across varying line voltages.
- The small power loss from PFC switching circuits has a negligible impact on hold-up time, easily compensated with minor capacitor sizing adjustments.
- For low-power applications, the difference in hold-up time between PFC and non-PFC is so small that other factors (cost, size, compliance) should drive the decision.

If you’re designing a power supply and need to nail down hold-up time specs while meeting efficiency and compliance requirements, we’ve engineered PFC solutions for applications from 100W IoT nodes to 15kW industrial chargers, with custom bulk capacitor sizing tailored to your exact hold-up time needs. Reach out to our team to discuss your project details.
PFC Power Supply References:
- Mohan, N., Undeland, T. M., & Robbins, W. P. (2003). Power Electronics: Converters, Applications, and Design (3rd ed.). John Wiley & Sons.
- IEC 61000-3-2:2019. Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase). International Electrotechnical Commission.
- 80 PLUS Program. (2022). “Power Supply Efficiency and Power Factor Requirements”. Climate Savers Computing Initiative.
Guangzhou Kaihui Electronics Co., Ltd.
Guangzhou Kaihui Electronics Co., Ltd. is one of the most professional pfc power supply manufacturers and suppliers in China, specialized in providing the best customized service. We warmly welcome you to buy high quality pfc power supply made in China here from our factory.
Address: 2F BLDG8, Standard Ind.Park, Dongchong Town, Nansha District 511453, Guangzhou, Guangdong, China
E-mail: amy@gzkaihui.com
WebSite: https://www.kaihuipowersupply.com/